г. Кострома, отдел продаж:
Приёмная: +7 (4942) 419-107
г. Москва, отдел продаж:
Приёмная: +7 (4942) 419-107

Our boilers

allboiler.ru

Boilers КВР

КВр 10
КВр 15
КВр 20
КВр 40
Order button

Do you have questions? Call:

+7 (4942) 622-023

Boiler design and operation:

The boiler is a steel cylinder surrounded by a steel cylinder of larger diameter, the construction is insulated. A thermostat is located in the front of the boiler. Heat carrying agent is heated between the two cylinders, the temperature and pressure of the agent is controlled by a thermomanometer. There are two manholes in the construction for the loading of firewood and for ash removal, closed by the upper and lower doors, and a chimney for flue gas evacuation. There are also nozzles for supply and removal of heat carrying agent. An air heating chamber is installed at the top of the combustion chamber to improve the quality of combustion and heat transfer.

There is an inlet between the heating chamber and the boiler walls through which the flue gases enter the heat exchange space.

A telescopic air supply pipe is placed in the chamber, consisting of sections at the end of which the air distributor is fixed. At the top of the chamber there is an air inlet and an air regulating device. On the left side of the boiler, next to the doors, there is a cable for lifting the telescopic air supply pipe. The purpose of the air distributor is to distribute the air properly in the heat generation zones located below, next to the air distributor, as well as in the combustion zones that are located near and above the distributor. The air distributor leans against the wood and descends down as the fuel burns.

Structural versions:

We can offer the following sizes of boilers КВР to our customers:

КВР-15 (power 15 kW, heated area 75 -150 m?);

КВР -20 (power 20 kW, heated area 100-220 m?);

КВР -40 (power 40 kW, heated area of ??200-450 m?).

These boilers can be used in heating systems of open and closed type. Depending on the customer’s needs, forced or arbitrary circulation of heat energy is provided. The water is used as a heat carrying agent going to radiator units.

The following fuel is used for these boilers:

• firewood;

• wood wastes (chips);

• sawdust fuel briquettes;

All these types of fuel are available and relatively inexpensive. Their humidity should not exceed 15-30%. Negative impact on the environment during the operation of solid fuel boilers is minimized, since these fuels produce a small amount of carbon dioxide during combustion, which positively affects the health of the household residents and the environment in general.

Specifications of BOILERS КВР

Power of boiler 10 кВт

15 кВт

20 кВт

40 кВт

Used fuel

Firewood, wood waste, sawdust briquettesrecommended humidity% 15-30

Heated area (m2) 50-110

75-170

100-220

200-450

Heated room volume (m3) 150-330

300 – 510

480 – 660

1140 – 1350

Volume of fuel (firewood) (kg) 24

30

50

90

Maximum length of firewood (sm) 35

35

40

45

  The amount of water in the boiler 23

30

38

45

The maximum flow rate of the heat carrier (cc / h) 0,25

0,375

0,5

1

Dimensions of connecting pipes
Diameter of coolant nozzles

Ду 32, (Муфта G1 1/4”)

The duration of combustion of fuel laying * (h)

От 6 до 25

Pressure 3

3

3

3

Discharge after the boiler (Pa) of the coolant in the boiler (bar) max 15-20

20 – 30

20 – 30

20 – 30

Diameter of the branch pipe of the chimney (8). Outer diameter (mm)  140

140

159

194

Dimensions of the loading aperture (MM) 232×270

232х390

232х390

232х390

Weight (kg) 180

230

270

360

Dimensions, mm
Height

 

1420

1780

1920

1920

Diameter

 

550

550

620

730