г. Кострома, отдел продаж:
Приёмная: +7 (4942) 419-107
г. Москва, отдел продаж:
Приёмная: +7 (4942) 419-107

Our boilers

allboiler.ru

Electric air heating units УВНЭ

УВНЭ-15-02 УХЛ 4 УВНЭ-30-01 УХЛ 4
УВНЭ-30-02 УХЛ 4 УВНЭ-45-01 УХЛ 4
УВНЭ-45-02 УХЛ 4 УВНЭ-65-01 УХЛ 4
УВНЭ-65-02 УХЛ 4 УВНЭ-90-01 УХЛ 4

For an accurate selection of this type of equipment, we suggest that you fill out a questionnaire and send it to our specialists in the order

Download the questionnaire
Order button

Do you have questions? Call:

+7 (4942) 622-023
Electric air-heating units  (УВНЭ) with radial fans  ВЦ14-46 and control box are designated for heating the air in air-heating systems of industrial, public, amenity, cultural, agricultural premises, as well as  in  sales  outlets,  repair  shops,  garages  and  as  a part  of  process  equipment.  At  that  ambient environment should not be dangerously explosive andshould not contain current-conducting dust.
Operation  conditions  –  moderate-cold  climate  (УХЛ)  of  the  4th category  of  location  as  per GOST15150-69.
Units are equipped with electric air-heaters of ВНЭ series.

Specifications of electric air heating units УВНЭ

Product name   Fan name  Power fan, KW 
Rate of rotation, min
УВНЭ-15-02 УХЛ4 ВЦ 14-46 №3,15 1,1 1500
УВНЭ-30-01 УХЛ4 1,1
УВНЭ-30-02 УХЛ4 1,1
УВНЭ-45-01 УХЛ4 2,2
УВНЭ-45-02 УХЛ4 2,2
УВНЭ-65-01 УХЛ4 ВЦ 14-46 №4 4
УВНЭ-65-02 УХЛ4 4
УВНЭ-90-01 УХЛ4 7,5

Note: drop in temperatures of supplied and discharged air is indicated for minimum air capacity, 100% of air-heater capacity taking into account positive tolerances for supply voltage and electric-heater power when supplied air temperature is 0 ° С.

Name of parameter  Parameter value 
УВНЭ-30-01 УВНЭ-45-01 УВНЭ-65-01 УВНЭ-90-01
Installed capacity, кВт 23,6/22,5 47,2/45,0 71,5/67,5 97,5/90,0
Air capacity, m3/h, not less
2000 3000 4000 7500
Temperature drop at supplied and
discharged air, ° С, not more
24 51 59 40
Aerodynamic resistance, Pa, not more
150 110 95 175
Design air pressure provided by fan, Pa,
not more
500 800 1400 1500
Rated main voltage, V 380±28,5
Current frequency, Hz 50
Number of phases 3
Weight, kg, not more 66 79 141 170
Name of parameter  Parameter value 
УВНЭ-15-02 УВНЭ-30-02 УВНЭ-45-02 УВНЭ-65-02
Installed capacity, кВт  15,5/14,4 29,9/28,8 45,4/43,2 61,6/57,6
Air capacity, m3/h, not less
2000 2500 3000 4000
Temperature drop at
supplied and
discharged air, ° С, not
more
24 39 49
Aerodynamic
resistance, Pa, not more
155 85 65
Design air pressure
provided by fan, Pa, not
more
500 800 1400
Rated main voltage, V 380±28,5
Current frequency, Hz 50
Number of phases 3
Weight, kg, not more 66 74 86 148

Overall dimensions of air-heater units УВНЭ

Product name
Dimensions, mm
A
H1
H2
L1
L2
a
b
c
d
e
l1
l2
УВНЭ-15-02 УХЛ4
390
560
660
1335
1340
340
221
241
261
65
600
1200
УВНЭ-30-01 УХЛ4
УВНЭ-30-02 УХЛ4
625
УВНЭ-45-01 УХЛ4
1350
УВНЭ-45-02 УХЛ4
695
УВНЭ-65-01 УХЛ4
322
845
852
1405
1380
290
280
300
320
40
650
1300
УВНЭ-65-02 УХЛ4
910
УВНЭ-90-01 УХЛ4
352
1455
1420
320
160